ASTM F146 PDF

F – 80 Standard Test Methods for Fluid Resistance Of Gasket Materials. Designation: F – Standard Test Methods for. Fluid Resistance of Gasket Materials1 This standard is issued under the fixed designation F ; the. ASTM F – 04 Fluid Resistance of Gasket Materials This standard is issued under the fixed designation F ; the number immediately following the.

Author: Kat Vudogis
Country: China
Language: English (Spanish)
Genre: Love
Published (Last): 26 May 2013
Pages: 241
PDF File Size: 2.12 Mb
ePub File Size: 6.87 Mb
ISBN: 620-6-56332-279-8
Downloads: 18461
Price: Free* [*Free Regsitration Required]
Uploader: Zulugrel

Exercise care when removing the excess fluid so that no squeezing action wstm on the sample. These test methods are not applicable to the testing of vulcanized rubber, a procedure that is described in Test Method D NOTE 1—Coolant mixtures are typically tested under boiling reflux conditions. We need your help!

Last previous atm approved in as F — The inch-pound units in parentheses are for information only. We are a non-profit group that run this website to share documents.

ASTM F – 80 Standard Test Methods for Fluid Resistance Of Gasket Materials

The change in thickness of the specimens is to be calculated as an expression of percentage change from the f416 thickness. The change in weight of the specimens is to be calculated as an expression of percentage change on the original weight. Please help us to share our service with your friends.

The results of these test methods are not intended to give any direct correlation with service conditions in view of the wide variations in temperature and special uses encountered in gasket applications. Measure the weight of the test specimen to the nearest 1 mg 0.

Please fill this form, we will try to respond as soon as possible. ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item ff146 in this standard. Dead weight loads are listed in Table 1.

  EDWARD LEEDSKALNIN PDF

Current edition approved April 1, The anvil shall have a diameter not less than that of the presser foot, which has a diameter r146 6.

The results of these test methods are not intended to give any direct correlation with service conditions xstm view of the wide variations in temperature and special uses encountered in gasket applications. Precision and Bias 7 Summary of Test Methods 3. These test methods are applicable to ethylene glycol, propylene glycol, commercial coolants and blends with water thereof see Note 1water, and other commercial oils and fuels.

Graduate the dial in 0.

There were six Type 1,7, three Type 3, and one Type 5 material evaluated for immersion weight change and thickness change in IRM oil. The specific test fluids and test conditions outlined were selected as typical for purposes of comparing different materials aetm can be used as a routine test when agreed upon between the purchaser and the manufacturer.

BoxTrenton, NJ Change the distilled water used in the test frequently. The producer must be aware that different coolant mixtures may yield different results.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Other physical property tests described in this standard are not applicable for these materials. Size px x x x x Use enough fluid to provide a minimum of 10 mL for each specimen in the container.

F — 04 Standard Test Methods for Fluid Resistance of Gasket Materials1 This standard is issued under the fixed designation F ; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. Significance and Use 4. A number in parentheses indicates the year of last reapproval.

  LG RVF1000 PDF

Pour enough fresh fluid into the tube to completely cover the specimens and ensure that they are immersed.

ASTM F 146 – 04

Pour enough fresh test fluid over the specimens to ensure that the specimens are wetted and covered by the fluid. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters.

Use the same sinker throughout. Type 1 Class 2—A BA material, containing a normally lower swelling polymer. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend.

ASTM F146 – 12

NOTE 2—Great care must be taken to record the f1446 thickness when the needle slows to a different rate which reflects indentation into the softened specimen. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

It is designed for testing specimens cut from gasketing materials or from finished articles of commerce. This gives the final volume, V2. This standard has been approved for use by agencies of the Department of Defense. The user should be aware that results may differ. Thank you for interesting in our services.

ICS Number Code